M5 Concept's LLC

Safe Rooms  *&*  Storm Shelters
M5 Concept's LLC

Safe Rooms  *&*  Storm Shelters
  • Home
  • MCF Products
  • Shelters
    • Products
    • In-Ground Storm Shelters
    • Above-Ground Safe Rooms
    • Builders and Pre-Slab
    • Commercial Shelters
  • Service Areas
    • Carthage MO Shelters
    • Sherman and Ada Shelters
    • Durant OK Shelters
    • Storm Shelters Oklahoma
    • Nationwide Delivery
  • Photos
    • Gallery
    • Recent Installations
  • FAQs & Info
    • Specifications
    • Testing & Compliance
    • Become a Dealer
    • Financing
    • Storm Shelter FAQ
  • Contact Us
  • More
    • Home
    • MCF Products
    • Shelters
      • Products
      • In-Ground Storm Shelters
      • Above-Ground Safe Rooms
      • Builders and Pre-Slab
      • Commercial Shelters
    • Service Areas
      • Carthage MO Shelters
      • Sherman and Ada Shelters
      • Durant OK Shelters
      • Storm Shelters Oklahoma
      • Nationwide Delivery
    • Photos
      • Gallery
      • Recent Installations
    • FAQs & Info
      • Specifications
      • Testing & Compliance
      • Become a Dealer
      • Financing
      • Storm Shelter FAQ
    • Contact Us
Get a Quote
  • Home
  • MCF Products
  • Shelters
    • Products
    • In-Ground Storm Shelters
    • Above-Ground Safe Rooms
    • Builders and Pre-Slab
    • Commercial Shelters
  • Service Areas
    • Carthage MO Shelters
    • Sherman and Ada Shelters
    • Durant OK Shelters
    • Storm Shelters Oklahoma
    • Nationwide Delivery
  • Photos
    • Gallery
    • Recent Installations
  • FAQs & Info
    • Specifications
    • Testing & Compliance
    • Become a Dealer
    • Financing
    • Storm Shelter FAQ
  • Contact Us
Get a Quote

Above-Ground Shelter Testing Documents

Above-ground shelter testing was conducted at Intertek in Plano, Texas.

Report No: Q9217.01-801-44-R0
Test specimen: 4 x 6-foot above-ground shelter.

Above-ground testing documents are available upon request. Confirm how the report applies to your selected size, configuration and local project requirements.

100 MPH Missile Impact Testing



The shelter successfully received all required ICC 500 missile impacts without perforation.

• No penetration through doors, walls, or roof

• Vision panel resisted impact

• Deformation remained within ICC limits

The product met ICC 500-2020 impact requirements.

M5 Concepts steel shelter door with visible marks from missile impact testing.

300 PSF Structural Pressure Testing



The shelter was subjected to positive and negative pressure testing up to 300 psf (200 psf design load).

Results:

• Structure remained intact

• Doors remained latched

• No structural failure

The shelter met ICC 500-2020 static pressure requirements.

Construction Details Tested



• 1/4” A36 steel plate walls and doors

• Fully welded vertical and horizontal connections

• Reinforced door perimeter

• Multi-point slide bolt latch system

• Deadbolt locking mechanism

• ICC-tested vision panel

Worker using an angle grinder on a steel component in the M5 Concepts workshop.

For Distributors & Contractors

Testing conducted at Intertek Building & Construction Laboratory

Report No: Q9217.01-801-44-R0

Testing Date: January 29–30, 2024

Full documentation available upon request.

Request Documentation